I have installed a BLUE SEA  "Add A BATTERY Dual Circuit System"  which has a Automatic Charging Relay. I plan to connect the start isolation input on the ACR to the Start Key and would like to know which is the correct terminal to connect to? I am assuming it would be the one going to the starter solenoid. I have a ABV Panel.

Thanks, Zoe



__________________


Senior Member

Status: Offline
Posts: 198
Date:

Hello Zoe,

I am sorry to say that we are unfamiliar with this product.

Before making a wrong guess with the starting circuit I would suggest contacting Blue Sea Systems directly.

Phone: 360-738-8230

or

E-Mail   conductor@bluesea.com



__________________

Best regards,

Farron

Technical Sales and Service for Beta Marine, US Ltd. Minnesott Beach, NC   PH: 252-249-2473  farron@betamarineusa.com



Member

Status: Offline
Posts: 7
Date:

Which contact on the Beta Marine key switch is the Start contact?

__________________


Senior Member

Status: Offline
Posts: 198
Date:

Hello Court,

The keyed switches use the terminal marked 17 for the starter motor circuit. A white wire with red stripe will be connected to the terminal.



__________________